The discrepancies produced by shear lag are minimal in rolled sections, which have relatively narrow and thick flanges. However in plate girders, or box sections, having wide thin flanges the effects can be significant when they are subjected to high shear forces, especially in the vicinity of concentrated loads where the sudden change in shear force produces highly incompatible warping distortions.