Prying action can be kept to a minimum by using the following measures:
- increasing the ratio a/b to at least 0,75;
- increasing the bolt spacing to at least 90 mm;
- increasing the end plate thickness to at least 1,25 times the bolt size.

Prying action can be kept to a minimum by using the following measures: