The activation of dowel action in the reinforcement bar occurs due to relative horizontal displacement of old and new concrete layer. For dowel action, it can be distinguished between the three mechanisms of bending, shear and a combined tension-shear (kinking), which occurs due to high displacements. Requirements for a full activation of dowel action is a sufficient concrete cover and a sufficient embedding depth of the reinforcing bar.