For reinforced concrete frame structures, movement joints at least 25mm wide should normally be provided at approximately 50m centres both longitudinally and transversely. In the top storey with an exposed […]
For reinforced concrete frame structures, movement joints at least 25mm wide should normally be provided at approximately 50m centres both longitudinally and transversely. In the top storey with an exposed […]
Movement joints may also be required where there is a significant change in the type of foundation, or the height or plan form of the structure.
Movement joints should divide the structure into a number of individual sections, and should pass through the whole structure above ground level in one plane.
Concrete floor slabs should have movement joints at around 20-30 m.
Masonry should have movement joints at around 7 m centres.