EK328
In a continuously reinforced concrete slab on ground that is without joints except for construction and expansion or isolation joints where needed, the percentage of distributed reinforcing steel is 0,6 […]
In a continuously reinforced concrete slab on ground that is without joints except for construction and expansion or isolation joints where needed, the percentage of distributed reinforcing steel is 0,6 […]
The combined shortening effect due to creep, shrinkage and temperature reductions induces tensile stresses in the precast components. The stresses must be accounted for in the connection design by either […]