The combined shortening effect due to creep, shrinkage and temperature reductions induces tensile stresses in the precast components. The stresses must be accounted for in the connection design by either providing stress relieve details in unrestrained joint or by providing additional reinforcing steels to resist tensile forces in a restrained joint.